Introduction
This is part of the Heirloom Computing Elastic Batch Platform forum on paas.heirloomcomputing.com.
Messages and codes for the Elastic Batch Platform are stored in the ebp application deployment directory under the Java EE application server. The messages may be internationalized by creating alternate forms of the ebp_en_US.properties file by creating alternate file names from alternative languages (default en) or locales (default US). Use your Java EE server's configuration to set the default language for your location.
Refer to a message or code you received in any support ticket you file with Heirloom Computing regarding EBP.
Below is the list of messages and codes found in ebp_en_US.properties.
p { margin-bottom: 0.1in; line-height: 120%; }
HCI000I |
HEIRLOOM COMPUTING INC - ELASTIC BATCH PLATFORM - JES/JCL %s |
HCI000D |
Heirloom Computing Inc - Elastic Batch Platform - JES/JCL %s |
HCI001D |
%s |
HCI001I |
%s |
HCI001W |
%s |
HCI001E |
%s |
HCI001S |
%s |
HCI002E |
EBP Internal Error - %s |
HCI003S |
EBP Internal Error - unknown error |
HCI004S |
EBP Internal Error - error during generation of servlet response |
HCI005D |
Web Service Request: %s %s |
HCI006I |
|
HCI101I |
$HASP101I JOB %5d %-8s STARTED ON CLASS %s |
HCI102I |
$HASP102I JOB %5d %-8s STOPPED |
HCI103I |
$HASP103I JOB %5d %-8s CANCELED |
HCI104I |
$HASP104I JOB %5d %-8s SUSPENDED IN STEP %s |
HCI111I |
$HASP111I JOB %5d %-8s STARTED ON CLASS %s |
HCI112I |
$HASP112I JOB %5d %-8s TERMINATED WITH %s |
HCI113I |
$HASP113I JOB %5d %-8s CANCELED ON CLASS %s |
HCI114E |
$HASP114E JOB %5d %-8s ABORTED - EXCEEDED MAX ELAPSED TIME (%d SECONDS) |
HCI115E |
$HASP115E JOB %5d %-8s FAILED TO START |
HCI116E |
$HASP116E JOB %5d %-8s EBP CAN ONLY EXECUTE JCL AND PYTHON JOBS |
HCI117I |
$HASP117I JCL SCAN %s |
HCI118I |
$HASP118I %s |
HCI119E |
$HASP119E ERROR AT:%s |
HCI120E |
$HASP120E JCL ERROR: %s |
HCI120I |
$HASP120I ERROR AT:%s |
HCI121E |
$HASP121E EXECUTION ABORTED DUE TO LAST ERROR MESSAGE: '%s' |
HCI122I |
$HASP122I ERROR AT:%s |
HCI122E |
$HASP122E JOB %5d %-8s ABORTED WITH JCL ERROR |
HCI123E |
$HASP123E CANNOT HAVE TWO JOB CARDS IN ONE JOB |
HCI124E |
$HASP124E JCL OUT OF ORDER .. NON-JOBLIB DD APPEARS BEFORE FIRST EXEC IN JOB |
HCI125I |
$HASP125I JOB ANALYSIS %s |
HCI126I |
$HASP126I %s ATTRIBUTE %s: %s |
HCI127E |
$HASP127E |
HCI128E |
$HASP128E JOB %5d %-8s STEP %-17s ABEND - PGM %s CANNOT BE FOUND OR IS NOT EXECUTABLE |
HCI128S |
$HASP128S EXECUTION EXCEPTION: '%s' |
HCI129E |
$HASP129E STEP %-17s DD %-8s WITH DISP=NEW COULD NOT BE CREATED (%s) |
HCI130E |
$HASP130E STEP %-17s DD %-8s CANNOT BE LOCKED FOR EXCLUSIVE USE (DISP=NEW, OLD OR CATLG) DSN %s |
HCI131E |
$HASP131E STEP %-17s DD %-8s CANNOT BE LOCKED FOR SHARED USE (DISP=SHR) DSN %s |
HCI132E |
$HASP132E STEP %-17s DD %-8s WITH DISP=DELETE COULD NOT BE DELETED DSN %s |
HCI133E |
$HASP133E STEP %-17s DD %-8s WITH DISP=OLD,SHR COULD NOT BE ACCESSED DSN %s |
HCI134E |
$HASP134E DD %s CANNOT BE CREATED |
HCI135I |
$HASP135I JOB %5d %-8s STEP %-17s STARTED |
HCI136I |
$HASP136I JOB %5d %-8s STEP %-17s TERMINATED WITH CC %s |
HCI137I |
$HASP137I JOB %5d %-8s STEP %-17s TERMINATED WITH ABEND %s |
HCI138I |
$HASP138I DATASET CREATION OR LOCK FAILURE -- REQUEUING JOB |
HCI139I |
$HASP139I JOB %5d %-8s REQUEUED ON CLASS %s |
HCI140E |
$HASP140E REQUEUE OF JOB FAILED - COULD NOT LOCK RESOURCE OR CREATE NEW DATASETS |
HCI141I |
$HASP141I JOB %5d %-8s STEP %-17s BYPASSED BECAUSE OF ABEND |
HCI142I |
$HASP142I JOB %5d %-8s STEP %-17s BYPASSED BECAUSE OF COND TEST |
HCI143E |
$HASP143E STEP %-17s COND REFERENCES NON-PRECEDING STEP %-17s |
HCI144E |
$HASP144E JOB STEP %-17s ABORTED - DD DSN NOT FOUND |
HCI145E |
$HASP145E CNTL GROUP %s DOES NOT PRECEDE REFERENCE IN DD %-8s IN STEP %-17s |
HCI146E |
$HASP146E CNTL GROUP %s OR CNTL GROUP STEP %s DO NOT EXIST; REFERENCED BY DD %-8s IN STEP %-17s |
HCI147E |
$HASP147E DUPLICATE STEP NAME %-17s |
HCI148E |
$HASP148E DUPLICATE DD NAME %-8s IN STEP %-17s |
HCI149E |
$HASP149E STEP NAME %-17s, DD NAME %-8s, CANNOT SPECIFY SPACE KEYWORD FOR DISP OLD, MOD OR SHR |
HCI150E |
$HASP150E JOB %5d %-8s ABORTED - EXCEEDED MAX CPU TIME (%d SECONDS) |
HCI151I |
$HASP151I JOB %5d %-8s SUBMITTED TO INTERNAL READER |
HCI152E |
$HASP152E INTERNAL READER SUBMIT FAILED: %s |
HCI153I |
$HASP122E JOB %5d %-8s FINISHED WITH TYPRUN=SCAN |
HCI154E |
$HASP154E JOB %5d %-8s FAILED - DATASET UNAVAILABLE |
HCI155E |
$HASP155E JOB %5d %-8s STEP %-17s ABEND - PROC CANNOT BE FOUND |
HCI156I |
$HASP156I JOB %5d %-8s REQUEUED FROM CLASS %s TO CLASS %s BECAUSE OF JOB TIME SPECIFICATION |
HCI157E |
$HASP157E JOB %5d %-8s HELD BECAUSE NO APPROPRIATE JOB CLASS DEFINED BASED ON JOB TIME SPECIFICATION |
HCI158W |
$HASP158W DD %-8s IN STEP %-8s INDICATES OUTPUT BUT JOB CONTAINS NO OUTPUT STATEMENTS, DEFAULT USED |
HCI159E |
$HASP158E DD %-8s IN STEP %-8s REFERENCES OUTPUT %s NOT FOUND IN THIS JOB |
HCI160W |
$HASP160W IGNORING ENDIF OR ELSE STATEMENT WITHOUT CORRESPONDING IF STATEMENT |
HCI161I |
$HASP161I JOB %5d %-8s STEP %-17s BYPASSED BECAUSE OF IF-THEN/ELSE |
HCI162W |
$HASP162W UNDEFINED SYMBOLIC PARAMETER '%s' REMOVED |
HCI163W |
$HASP163W INVALID UNIX PERMISSION '%s' IGNORED |
HCI164W |
$HASP164W INVALID UNIX OPEN OPTION '%s' IGNORED |
HCI165E |
$HASP165E JOB DD %s MUST BE NAMED JOBLIB |
HCI166E |
$HASP166E FIRST EXEC DD MUST BE NAMED |
HCI167I |
$HASP167I JOB %5d %-8s RESTART AT STEP %s |
HCI168W |
$HASP168W %s LIBRARY %s IGNORED - NOT FOUND OR NOT ACCESSIBLE FROM SERVLET CONTAINER |
HCI169I |
$HASP169I JOB %5d %-8s PURGED DUE TO AGING |
HCI170E |
SYNTAX ERROR, EXPECTED '%s' BUT RECEIVED '%s' |
HCI171E |
SYNTAX ERROR, UNEXPECTED CHARACTER |
HCI172E |
$HASP172E JCL DECK CANNOT BE READ (FILE %s) |
HCI200I |
IUTIL200I HEIRLOOM COMPUTING INC - JOB UTILITIES |
HCI201I |
IUTIL201I %s UTILITY PROGRAM |
HCI202I |
IUTIL202I READING CONTROL CARDS |
HCI203I |
IUTIL203I %03d CONTROL CARDS READ |
HCI204I |
IUTIL204I CONTROL CARD: %s |
HCI205E |
IUTIL205E ERROR %s |
HCI206W |
IEBGE206W UTILITY PARAMETERS (%s) IGNORED |
HCI207E |
IEBGE207E MISSING REQUIRED DD NAME %s OR DATASET CANNOT BE OPENED |
HCI208I |
IEBGE208I IEBGENER STARTING: COPYING SYSUT1 TO SYSUT2 |
HCI209I |
IEBGE209I IEBGENER COMPLETED, CC=%d |
HCI210W |
IEBGE210W IEBGENER CONTROL CARDS IGNORED (CASE NOT HANDLED AT THIS TIME) |
HCI211S |
IEBGE211S IEBGENER CANNOT OPEN %d. REQUIRED RUNTIME ecobol.jar NOT IN CLASSPATH OR NOT AVAILABLE FROM SERVLET CONTAINER |
HCI212E |
IEBGE212E IEBCOPY ACTS ON PARTITIONED DATASETS, %s DOES NOT SPECIFY A DIRECTORY |
HCI213I |
IEBGE213I IEBCOPY STEP %s STARTING |
HCI214I |
IEBGE214I IEBCOPY STEP %s COMPLETED: %03d MEMBER%s PROCESSED, CC=%d |
HCI215E |
IEBGE215E COULD NOT COPY MEMBER %s AS IT EXISTS IN OUTDD AND REPLACE NOT SPECIFIED |
HCI216I |
IEBGE216I COPIED DD %s(MEMBER %s) TO DD %s(MEMBER %s) |
HCI216E |
IEBGE216E COULD NOT COPY FROM DD %s(MEMBER %s) TO DD %s(MEMBER %s) I/O ERROR |
HCI217E |
IEBGE217E COULD NOT OPEN DD %s(MEMBER %s) |
HCI218W |
IEBGE218W COULD NOT COPY MEMBER %s AS IT WAS NOT FOUND IN ANY INPUT DATASET |
HCI219I |
IEBGE219I PROCESSING MEMBER: %s |
HCI220D |
IUTIL220D DATASET %s CANNOT BE OPENED |
HCI221D |
IUTIL221D DATASET %s CANNOT BE CREATED |
HCI222D |
IUTIL222D DATASET %s OPENED %s |
HCI223D |
IUTIL223D DD NAME %s NOT DEFINED |
HCI230I |
IDCAM230I IDCAMS %s STARTING |
HCI231I |
IDCAM231I IDCAMS %s FUNCTION COMPLETED, HIGHEST CONDITION CODE WAS %d |
HCI232E |
IDCAM232E DATASET %s CANNOT BE OPENED |
HCI233E |
IDCAM233E DATASET %s CANNOT BE CREATED |
HCI234E |
IDCAM234E DATASET %s OPENED %s |
HCI236E |
IDCAM236E I/O OPERATION FAILED ON %s |
HCI237E |
IDCAM237E DATASET %s DOES NOT EXIST |
HCI238S |
IDCAM238S DATASET %s CANNOT BE DELETED |
HCI239E |
IDCAM239E IMPLEMENATION RESTRICTION: CANNOT SET %s |
HCI240E |
IDCAM240E DATASET %s IS NOT A GDG |
HCI241I |
IDCAM241I DATASET %s DELETED |
HCI242I |
IDCAM242I %s %s %s DELETED |
HCI243S |
IDCAM243S ISAM DATASET %s CANNOT BE CREATED OR ECOBOL.JAR IS MISSING FROM $CLASSPATH |
HCI244I |
IDCAM244I REPRO %d RECORDS |
HCI245I |
IDCAM245I REPRO %d BYTES |
HCI246E |
IDCAM246E DATASET %s ALREADY EXISTS, DEFINE WILL NOT REPLACE IT |
HCI247I |
IDCAM247I IDCAMS OPERTION SKIPPED DUE TO CC %d>=8 |
HCI248E |
IDCAM248E CAN ONLY SET 'LASTCC' OR 'MAXCC' |
HCI250I |
SORT0250I %s |
HCI250E |
SORT0250E INPUT JCL DATASET '%s' CANNOT BE FOUND IN CURRENT WORKING DIRECTORY (JOB TEMP_SPOOL LOCATION) |
HCI251E |
SORT0251E SORT RESTRICTED TO FORMATS 'CH', 'AC', 'ZD', 'ASL', 'UFF', 'SFF'; '%s' IS INVALID |
HCI252E |
SORT0252E SORT REQUIRES %s DD CARD |
HCI253D |
SORT0253D USING DD '%s' AS FILE '%s' |
HCI254D |
SORT0254D ISSUING COMMAND '%s' |
HCI255S |
SORT0255S SEVERE ERROR: %s |
HCI256I |
SORT0256I %s STARTING |
HCI257I |
SORT0257I %s COMPLETED, CC=%d |
HCI258E |
SYNCSORTE MAPFILE CANNOT BE CREATED IN CURRENT WORKING DIRECTORY (JOB TEMP_SPOOL LOCATION) |
HCI259E |
SYNCSORTE DDNAME=DSNAME COMMAND PARAMETERS NOT SPECIFIED |
HCI260I |
IKJEF260I %8s %s STARTING |
HCI261I |
IKJEF261I %8s %s COMPLETED, CC=%d |
HCI262E |
IKJEF262E TSO %s COMMAND REQUIRED PARAMETER NOT SUPPLIED |
HCI263E |
IKJEF263E TSO DSN COMMAND REQUIRES IKJEFT.PROPERTIES FILE WHICH IS NOT FOUND |
HCI264E |
IKJEF264E TSO DSN COMMAND SYSTEM %s ATTRIBUTES NOT FOUND IN IKJEFT.PROPERTIES FILE |
HCI265E |
IKJEF265E TSO DSN SYSTEM(%s) COMMAND COULD NOT OPEN DATABASE '%s' |
HCI266E |
IKJEF266E TSO RUN COMMAND REQUIRED PROGRAM OPERAND MISSING |
HCI267E |
IKJEF267E TSO RUN COMMAND COULD NOT FIND PROGRAM '%s' in CLASSPATH |
HCI268I |
IKJEF268I TSO RUN PROGRAM(%s) SQL CONNECTION PASSED AS 'conn' CONNECTION OBJECT |
HCI269I |
IKJEF269I TSO RUN PROGRAM(%s) SQL CONNECTION PASSED AS SYSTEM PROPERTIES |
HCI270E |
IKJEF270E TSO RUN PROGRAM(%s) HAS NO '%s' METHOD |
HCI271E |
IKJEF271E TSO RUN PROGRAM(%s) METHOD '%s' FAILED WITH '%s' |
HCI272I |
IKJEF272I TSO RUN PROGRAM(%s) RETURNED WITH CONDITION CODE '%s' |
HCI273I |
IKJEF273I TSO IMPLICIT DSN SYSTEM(%s) COMMAND COULD NOT OPEN DATABASE '%s' (IGNORED) |
HCI274I |
IKJEF274I TSO DSN SYSTEM(%s) COMMAND OPENED DATABASE '%s' |
HCI275I |
IKJEF275I TSO IMPLICIT DSN SYSTEM(%s) CONFIGURED DRIVER CLASS '%s' COULD NOT BE LOADED (IGNORED) |
HCI275E |
IKJEF275E TSO DSN SYSTEM(%s) CONFIGURED DRIVER CLASS '%s' COULD NOT BE LOADED |
HCI276I |
IKJEF276I TSO RUN PROGRAM(%s) RETURNED WITH ABEND CODE '%s' |
HCI280E |
DSNTI280E DATABASE NOT CONNECTED |
HCI281E |
DSNTI281E SQL EXCEPTION: '%s' |
HCI282W |
DSNTI282W NO SQL STATEMENTS IN SYSIN (OR NOT TERMINATED WITH ;) |
HCI283I |
DSNTI283I EXECUTED %d SQL STATEMENTS |
HCI284I |
DSNTI284I %s |
HCI285W |
TMSCL285W UTILITY PARAMETERS (%s) IGNORED |
HCI286I |
TMSCL286I TMSCLEAN STARTING |
HCI287I |
TMSCL287I SCRATCHING VOLUME %s (EXPIRATION DATE %s) |
HCI288I |
TMSCL288I TMSCLEAN FINISHED: %d TOTAL VOLUMES SCRATCHED |
HCI301E |
$HASP301E PROC %s CANNOT BE FOUND AMONG JOB JCLLIB OR SYSTEM CATALOG PROCEDURE LIBRARIES |
HCI302E |
$HASP302E CANNOT OPEN CATALOGED PROCEDURE FILE %s |
HCI303E |
$HASP303E CANNOT PARSE CATALOGED PROCEDURE %s |
HCI304I |
-------------------- CATALOGED PROCEDURE %s -------------------- |
HCI305E |
$HASP305E JOB CONTAINS NO EXECUTABLE STEPS |
HCI306E |
$HASP306E PROC %s CANNOT BE READ OR DOES NOT CONTAIN PROC/PEND |
HCI601E |
$HASP601E EBP INTERNAL ERROR - ERROR MSG FORMAT ON MSG %s |
HCI701E |
$HASP701E Parameter '%s' not in the required format '%s' |
HCI702E |
$HASP702E Parameter '%s' not defined for this service, valid parameters are '%s' |
HCI703E |
$HASP703E One or more required parameters to this service are missing, parameters are '%s' |
HCI704E |
$HASP704E SUBMIT must POST or PUT a script or deck |
HCI705E |
$HASP705E Class '%s' type '%s' inconsistent with job deck determined to be of type '%s' |
HCI706E |
$HASP706E Class '%s' not defined |
HCI707E |
$HASP707E No class defined of type '%s' matching the submitted job deck |
HCI708E |
$HASP708E Submitted job has errors: %s, not queued to class '%s' |
HCI709E |
$HASP709E Step and DDName '%s' dataset not generated in job '%d' |
HCI710E |
$HASP710E Initiator '%d' of class '%s' not running |
HCI711E |
$HASP711E No initiators of class '%s' are running |
HCI712E |
$HASP712E Class '%s' already defined" |
HCI713E |
$HASP713E No job ID '%d' in the output queue |
HCI714E |
$HASP714E No job named '%s' in the output queue |
HCI715E |
$HASP715E Multiple jobs named '%s' in the output queue - use job ID to distinguish |
HCI716E |
$HASP716E No job ID '%s' in the appropriate queue and state to be %s |
HCI717E |
$HASP717E No job named '%s' in the input queue |
HCI718E |
$HASP718E UNUSED |
HCI719E |
$HASP719E Job '%s' output not ready |
HCI720E |
$HASP720E Cannot execute COBOL / Java script '%s' |
HCI721I |
$HASP721I '%s' |
HCI722E |
$HASP722E Job type '%s' inconsistent with what is defined for class '%s' |
HCI723E |
$HASP723E Job '%s' in state '%s' cannot be canceled |
HCI724E |
$HASP724E Job '%s' in state '%s' is not checkpointable |
HCI725E |
$HASP725E Job '%s' in state '%s' is not restartable |
HCI726E |
$HASP726E Job '%s' in state '%s' could not be checkpointed |
HCI727E |
$HASP727E Job '%s' in state '%s' could not be restarted |
HCI730E |
$HASP730E Configuration parameter '%s' not defined, settable and/or viewable with your current role |
HCI731E |
$HASP731E Submitted job must start with "//" (JCL deck), "#" (Python script) or COBOL or Java jar magic number |
HCI732E |
$HASP732E No job named '%s' in the output queue |
HCI733E |
$HASP733E Can't purge running job '%s' - use cancel instead |
HCI801S |
EBP Subscription Check: %s |
HCI802I |
EBP operating under subscription for %s (%s) |
HCI803E |
Could not find elasticcobol.properties file in Application Server's user's home directory. Subscription required to operate this product. See https://paas.heirloomcomputing.com/ for more info. |
HCI804E |
EBP / Scheduler communication error |
HCI805I |
EBP accepting %s tasks for application '%s' as EBP ID '%s' from scheduler at '%s' |
HCI806I |
EBP accepting Heirloom %s tasks for application '%s' as EBP ID '%s' from scheduler at '%s' |
HCI807E |
Scheduler returned error: %s (error turned scheduler off: %b) |
HCI808E |
Scheduler returned incomplete information for task %s (error turned scheduler off: %b) |
HCI809E |
Scheduler returned incomplete information for job %s (error turned scheduler off: %b) |
HCI810E |
Scheduler could not retrieve deck for job %s (error turned scheduler off: %b) |
HCI811E |
Scheduler could not retrieve deck for job %s from local file %s (error turned scheduler off: %b) |
HCI812E |
Scheduler could not retrieve deck for job %s from local file %s in JclLib or SystemLib (error turned scheduler off: %b) |
HCI813D |
No scheduled tasks for '%s' (%s) and application '%s' |
HCI814E |
EBP failed to read output dataset '%s' (error turned scheduler off: %b) |
HCI815E |
EBP failed to post output dataset '%s' to scheduler location '%s' (error turned scheduler off: %b) |
HCI816I |
Skipping task '%s' (%s), locked by another EBP '%s' |
HCI817E |
Skipping task '%s' (%s), submit failed |
HCI818E |
Error uploading output dataset '%s' to cloud storage: '%s' |
HCI819I |
Incoming scheduled job task '%s' (%s) |
HCI820I |
Outgoing output dataset task '%s' (%s) |
HCI821I |
When operating EBP on-premise, subscribe to the product at https://paas.heirloomcomputing.com/, download a license file and place it in the Application Server user's home directory or the webapps/ebp directory. |
HCI822I |
Incoming scheduled initiator task '%s' (%s) |
HCI823I |
Incoming scheduled terminate (quiesce) task '%s' (%s) |
HCI824I |
Scheduler returned more tasks based on previous task completion |
HCI824W |
No valid Data Lib (config datalib.1..9) directory found, DISP=OLD DDs cannot be located |
HCI825W |
No writable Data Lib (config datalib.1..9) directory found, DISP=NEW DDs cannot be created |
HCI826W |
Temporary spool directory is not writable (config tempspool), IMMEDIATE datasets cannot be created |
HCI827W |
No valid System Lib (config systemlib.1..9) directory found, PGM=xxx will not be located |
HCI828W |
No valid JCL Lib (config jcllib.1..9) directory found, external PROCs will not be located |
HCI829W |
No valid Class Lib (config classlib.1..9) directory found, program dependent may not load |
HCI901E |
HCI901E License error HCI%03d |
HCI902I |
EBP-Plex node '%s' enabled %s peer '%s' |
HCI903E |
Both 'ebpplexnode' and 'ebpplexpeer' must be configured for EBP-Plex operation |
HCI904I |
EBP-Plex node '%s' learned of new peer '%s' |
HCI905D |
EBP-Plex node '%s' received '%s' from peer '%s' |
HCI906E |
EBP-Plex node '%s' disabled, could not contact ebpplexpeer '%s' [%s:%s] |
HCI907D |
EBP-Plex node '%s' sent '%s' to peer '%s' |
HCI908I |
EBP-Plex node '%s' forgetting about peer '%s', could not contact [%s:%s] |
HCI911E |
LOCK Web service error: XML tags 'oper' and 'from' are required |
HCI912E |
LOCK Web service error: %s operation |
HCI913E |
LOCK Web service error: Loopback -- 'ebpplexpeer' and 'ebpplexnode' are the same |
HCI914E |
CONFIG Web service error: Could not restore configuration from this file |
HCI915W |
Buffer Size param exceeds limit of 2147483647 bytes. Defaulting to 2147483647 bytes |
HCI916I |
Deploy properties Info: %s |
HCI917W |
The string rule %s is wrong! Default collator instance will be used. |
HCI918E |
Output file %s cannot be created because the name already exists. |
HCI919W |
Record length specified in the JCL - %d is different from the record length in the DCB - %d. The one from the JCL is going to be used. |
HCI920W |
Record type specified in the JCL - %s is different from the record type in the DCB - %s. The one from the JCL is going to be used. |
HCI921E |
Expression \n %s \n doesn't have the right order or number of brackets!\nCheck if the length of the statement has exceeded 72 characters. |
1 Comments